Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Eur J Orthop Surg Traumatol ; 27(3): 301-308, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28238043

RESUMO

INTRODUCTION: Cemented stem remains the gold standard for prosthesis in trauma. The purpose of this study was to evaluate the functional and radiological outcomes of a cementless, trauma-specific locked stem (hemi and reverse) for 3- and 4-part proximal humeral fractures. MATERIALS AND METHODS: One hundred and thirty-four 3- and 4-part fractures have been treated by locked stem, 69 with hemiarthroplasty [mean age 68 years (50-90)] and 65 with reversed [mean age 78 years (66-91)]. The length of the stem was 15 cm with a proximal coating of HA automatic locking system (two screws) and four different diameters. Preliminary cadaver study allowed us to validate the system (22 shoulders, no injuries of nerves, locking system efficient). RESULTS: In the group of hemi, Constant score with ponderation reached 72 (11-120) and QDash 31.2 (4.5-77.27) with a mean FU of 25 months (6-96). In the group of reversed, Constant score with ponderation reached 77.6 (28.8-119) and QDash 36.2 (2-84) with a mean FU of 15 months (6-41). Specific complications due to locking system reached 3% but without reoperation. Other complications were capsulitis and infection. DISCUSSION: In this population of elderly patient, new fall with periprosthetic fracture or infection led the surgeon to remove the stem. At shoulder level, the removal of a cemented stem remains a highly demanding procedure with sometimes bad functional results and elevated level of complications. This series is the first one of locked stem without significant complications. Locked stem remains a new but logical tool in trauma.


Assuntos
Artroplastia do Ombro/instrumentação , Hemiartroplastia/instrumentação , Fraturas do Ombro/cirurgia , Articulação do Ombro/fisiopatologia , Prótese de Ombro , Idoso , Idoso de 80 Anos ou mais , Artroplastia do Ombro/métodos , Cadáver , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Amplitude de Movimento Articular , Fraturas do Ombro/fisiopatologia , Articulação do Ombro/diagnóstico por imagem
2.
Hand Surg Rehabil ; 35S: S24-S27, 2016 12.
Artigo em Francês | MEDLINE | ID: mdl-27890206

RESUMO

None of the classification systems for distal radius fractures is ideal. However a validated system to analyze these fractures is available that is based on the "metaphysis, epiphysis, ulna" (MEU) classification and the "patient, accident, fracture" (PAF) system. It makes it possible to understand the injury and select the best treatment.


Assuntos
Fraturas do Rádio/classificação , Ossos do Carpo/diagnóstico por imagem , Epífises/diagnóstico por imagem , Humanos , Radiografia , Fraturas do Rádio/diagnóstico por imagem , Ulna/diagnóstico por imagem
3.
Orthop Traumatol Surg Res ; 102(3): 279-85, 2016 05.
Artigo em Inglês | MEDLINE | ID: mdl-26993853

RESUMO

INTRODUCTION: The reversed shoulder prosthesis is becoming the gold standard for cases of complex fracture of the proximal humerus after 70 years of age. MATERIAL AND METHODS: The French Society of Orthopaedic and Traumatology Surgery (SOFCOT) conducted a prospective and retrospective multicenter study to evaluate the results of the reversed shoulder prosthesis implanted in patients with a four-part fracture in nine centers. In the retrospective study (n=41 patients, 78 years of age, 14% ASA grade 3, 21% associated fractures) and in the prospective study (n=32 patients, 79 years of age, 37% ASA grade 3, 21% associated fractures) evaluation by independent surgeons was conducted to measure the QuickDASH score, the Constant score, the SSV (subjective shoulder value), and complications to correlate these measurements with radiological results. RESULTS: In both studies, use of an autograft (75%) to perform an osteosuture of tuberosities (90%) and no postoperative immobilization (75%) were similar. In the retrospective study at 39 months (range: 24-62 months) of follow-up, the QuickDASH reached 28 (range: 0-59), the Constant scores (raw Constant=57, weighted Constant=83.4%), and SSV 75 (range: 35-100). Complications after the 1st month (7%) were nonunion or ossifications. In the prospective study at 11 months (range: 5-16.5 months) of follow-up, the QuickDASH reached 40 (range: 1-75), the Constant scores 50 (raw Constant) and 74.6% (weighted Constant), and SSV 69 (range: 10-100). Complications after the 1st month (21%) were stiffness and dislocation, with two patients who underwent revision surgery. In both studies, early complications reached 6% (palsy, dislocation). CONCLUSION: This double (retrospective and prospective) study confirms the good results with a low level of complications of the reversed implant in cases of fracture but with osteosuture of tuberosities.


Assuntos
Artroplastia do Ombro/instrumentação , Fraturas do Ombro/cirurgia , Prótese de Ombro , Idoso , Idoso de 80 Anos ou mais , Artroplastia do Ombro/métodos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Estudos Retrospectivos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...